DSC Power Series

|
|
PowerSeries control panels have a proven reputation for providing the value and dependability that security professionals expect from their alarm panels.
|
PC1864 (8 to 64 Zones)
- 8 on-board zones
- 64 hardwired zones
- 32 wireless zones
- 4 PGM outputs; expandable to 14 (PC5204, PC5208)
- 8 partitions
- 500-event buffer
- CP-01 compliant
|
PC1832 (8 to 32 Zones)
- 8 on-board zones
- 64 hardwired zones
- 32 wireless zones
- 2 PGM outputs; expandable to 14 (PC5204, PC5208)
- 4 partitions
- 500-event buffer
- CP-01 compliant
|
PC1616 (6 to 16 Zones)
- 6 on-board zones
- 16 hardwired zones
- 16 wireless zones
- 2 PGM outputs; expandable to 14 (PC5204, PC5208)
- 2 partitions
- 500-event buffer
- CP-01 complianct
|
PC580/585 (Power432) (4 to 32 Zones)
- 4 on-board zones
- Expandable using wireless modules and keypad zones
- 128-event buffer
- 2 PGM outputs
|
Self-Contained Wireless Alarm System PowerSeries 9047
- Smallest footprint of any self-contained wireless alarm system currently available
- Built-in 2-way audio VOX and push-to-talk alarm communication
- Supports 32 wireless zones and 16 wireless keys (without using a zone slot)
- Full 32-character programmable phrases
- Enlarged keypad buttons
- 5 programmable function keys
- 1 partition
- 128-event buffer
- CP-01 compliant
|
Power Series 9047 |
Alexor 2-Way Wireless Panel PC9155
NEW 1st Quarter 2009!!
- 32 wireless zones, 16 wireless keys (without using a zone slot)
- Wireless quick enroll
- Template programming
- 16 user codes, 1 master code and 1 maintenance code
- Account code error checking (patent pending)
- Alternate communications via GSM/GPRS and IP
- Onboard siren at 85dB
- 2 Input/Output terminals
- 200mA Aux Output
- 500 event buffer
- Wall and case tamper
- 24Hr Battery backup
|

Alexor PC9155 |
Power Series Keypads

|
| |
|
FEATURES |
PC1864 |
PC1832 |
PC1616 |
|
On-Board Zones |
|
|
|
|
Total Zones Supported |
|
|
|
32 |
Hardwired Zones |
64 (7 x PC5208) |
32 (3 x PC5208) |
16 (2 x PC5208) |
- |
Wireless Zone Expansion |
Yes (32 wireless) |
Yes |
Yes |
Yes |
Number of Keypads |
8 |
8 |
8 |
8 |
Number of Access Codes |
94 + Master Code |
71 + Master Code |
47 + Master Code |
32 + Master Code |
Number of Partitions |
8 |
4 |
2 |
1 |
Panel Event Buffer |
500 |
500 |
500 |
128 |
SIA CO-01 Compliant |
No |
Yes |
Yes |
Yes |
GSM Alarm Communications |
Yes |
Yes |
Yes |
Yes |
|
GE Security NetworX Series 
|
|
With a NetworX® security system from GE Security, you have peace of mind that your home or business is equipped with the most advanced and reliable security technology available. NetworX systems are proven in applications from single family homes to commercial buildings with multiple businesses.
Proven in millions of residential and commercial applications throughout the world, GE control panels are well recognized for high quality and reliable performance. Whether the application is a single story residence, a school or multi-story government building, GE has the right panel for the job.
The flexibility and functionality the GE Security control panel system is a result of their commitment to provide innovative technology solutions that are easy to operate. GE control panels connect to a variety of keypads, key fobs, motion sensors, environmental sensors, glassbreak sensors, magnetic contacts, and fire/life-safety devices, which makes creating a customized solution simple.
All NetworX systems contain the Control Panel, One Keypad, Sentrol PI-6000 motion sensor (optional), 15W speaker, RJ cord & block, transformer, and battery.
|
GE Security NX-8E Alarm System (6 to 16 Zones)
- Expandable to 192 fully programmable zones
- All zones programmable as fire or burglary
- Maximum 24 keypads
- Wireless expansion up to 192 zones
- Maximum 8 keypads per partition
- Assign zones to one or multiple partitions
- 240 four digit or 166 six digit user codes
- Zone activity monitor
- Built-in RS-232 serial interface for printer or direct computer connect (Adapter cable needed)
- 2 amp power supply
- 512-Event History
|
GE Security NX-8 Alarm System (8 to 48 Zones)
- Expandable to 48 fully programmable zones
- All zones programmable as fire or burglary
- Maximum 24 keypads
- Wireless expansion up to 48 zones
- Maximum 8 keypads per partition
- Assign zones to one or multiple partitions
- 99 four digit or 66 six digit user codes
- Built-in siren driver/voltage out
- 185-Event History
|
GE Security NX-6 Alarm System (6 to 16 Zones)
- 6 fully programmable zones
- Wireless expansion up to 16 zones
- All zones programmable as fire or burglary
- 2 true partitions
- Maximum 8 keypads per partition
- Automatic arming with auto retry
- 40 user codes (4 or 6 digit)
- Built-in siren driver/voltage out
- 185-Event History
|
GE Security NX-4 Alarm System (4 to 8 Zones)
- 4 fully programmed zones
- All zones programmable as fire or burglary
- 8 user codes
- 1 duress code
- Modular design with slide in PC boards
- Siren supervision
- Automatic arming with auto retry
|
GE Security NetworX Keypads
|
|
FEATURES |
|
|
|
|
Programmable Zones (expandable to) |
8 (192) |
8 (48) |
6 (16) |
4 (8) |
User Codes 4-digit (6-digit) |
240 (166) |
99 (66) |
40 (40) |
8 (8) |
True Partitions |
8 |
8 |
2 |
None |
Event Log (Events) |
Yes (512) |
Yes (185) |
Yes (185) |
Yes (185) |
Maximum Number of Keypads |
32 |
32 |
16 |
8 |
Number of Expansion Modules |
3 |
3 |
3 |
1 |
3 Keypad Activated Emergency Keys |
Yes |
Yes |
Yes |
No |
Auto Arming |
Arm & Disarm |
Yes |
Yes |
Yes |
|
| |
|
GSM Communicators
The GSM Communicator is installed between the telephone connection of a
control panel and telephone line. When used in a backup role, the
communicator assesses the connection to the PSTN phone line,
and if that has failed, it then connects to the GSM network to send
an alarm signal to the monitoring station. In a primary role, the
communicator simply sends the alarm transmission over the GSM
network immediately.
The DSC GSM-3055i universal wireless alarm
communicator can be used in a backup or primary role.
The GS3055-I connects the alarm control panel to the GSM
network and reports alarm signals directly to a monitoring
station receiver (Sur-Gard™ System II/System III). For those
customers not using a traditional PSTN phone line, the
communicator can be utilized as a primary alarm
communicator. The GS3055-I uses the GPRS data channel of
the GSM network to ensure low-cost, high-speed and
reliable alarm communications and is compatible with any
control panel that communicates using the
Contact ID format.
|

|
- Compatible with any control panel that communicates
using the Contact ID format
- Full event reporting
- Uses GPRS data channel for high-speed, reliable
and low-cost communications to an IP receiver
- 4 on-board inputs
- 4 on-board outputs (open collector)
- SIM card (included)
- Activation and initialization via the automated telephone
activation system (VRU) or web-user interface provided
by CONNECT 24™
- Advanced programming via web-user interface
- Compatible with Sur-Gard System II/III monitoring station receivers
- Special rate plans and administration through CONNECT 24
UL/ULC listed
|
| |
|
Email us with questions or for more information about Burglar Alarm Systems |
| |